Agilent Technologies E5810A Network Card User Manual


 
54 Chapter 2
Installing the E5810
Configuring the E5810 on a Local Network
Example:
Configuring the
E5810
This example shows one way to set various E5810 parameters on the
Configuring your E5810 LAN/GPIB Gateway page, assuming the Enterprise
network to which the E5810 will be connected does not support DHCP or
DNS. Since the network does not support DNS, a Hostname cannot be used
for this E5810. In addition, it is assumed the network does not allow UPnP,
so Universal Plug and Play is set to OFF.
Configuring the
E5810 for Local
Network Operation
If you plan to install your E5810 on a Local network, use the Configuring
your E5810 LAN/GPIB Gateway
page to set the parameters applicable to your
Local network.
Where to go Next
To Install the E5810 on an Enterprise Network. Disconnect the E5810
from the Local network and go to “Installing the E5810 on an
Enterprise Network”.
To Use the E5810 on a Local Network. Leave the E5810 connected to
the Local network and go to “Verifying Instrument Communication”.
1. Set DHCP OFF
Enter New IP Address
Enter New Subnet Mask Value
Enter New Default Gateway IP Address
Leave DNS Server Address Blank
Leave Hostname Blank
Set Universal Plug and Play to OFF.
3. Click Reboot E5810 to reboot
and make changes effective
2. Click the Save button
to save changes