APC UPS control system Power Supply User Manual


 
Technical Reference
Configuration Directive Reference
Configuration directives in /etc/apcupsd/apcupsd.conf control the behavior
of the apcupsd daemon. For most installations it is only necessary to set a
handful of general directives. The rest can be left at their defaults unless
you have an exotic configuration.
General Configuration Directives
In general, each of these directives is required (ecept that the DEVICE
directive is ignored for UPSCABLE ether).
UPSTYPE <type of APC UPS you have> The name of a driver.
Should be one of dumb, apcsmart, net, usb, snmp, or test. This de-
scribes your interface type.
The UPSTYPE directive can be defined during installation by using
the --with-upstype= option of the ./configure program.
UPSCABLE <type of cable you are using>>
[ simple | 940-0020B | 940-0023A ]
[ smart | 940-0024B | 940-0024C ]
[ 940-1524C | 940-0024G | 940-0095A | 940-0095B | 940-0095C | 940-0119A]
[ ether | usb ]
The --with-upscable= option of ./configure can be used to set a
default for this directive during the your build.
DEVICE <name of device> Specify which device is used for UPS com-
munications. For serial ports, it is usually something like /dev/ttyS0.
For USB ports, you may leave the name of the device blank (no speci-
fication) and apcupsd will automatically search the standard locations
for the UPS.
Normally, the ./configure program will set an appropriate default
value. You may also specify the --with-serial-dev= option of the
./configure program to set this directive at build time.
If you have specified UPSTYPE net, then the device name to be
specified consists of hostname:port where the hostname is the fully
164