Barco G500 Projector User Manual


 
11. Image files menu
Advanced video settings
Image 11-8
The advanced button enables the advanced settings for a video source.
video signal
video signal
frame blanking
HI
egalisation
Image 11-9
HI AGC Hold interval
The Comb filter is by default enabled.
The AGC hold interval is the time interval in which the AGC is inhibited (AGC hold = no update in video amplitude measurement),
the advanced parameter allows to choose a short or long hold interval.
A long AGC hold interval eliminates Macrovision
®
disturbances since the AGC is hold during a long interval, thus reducing the
probability to encounter a Macrovis
ion
®
pulse.
The sync locking setting is recommended for poor video signals (ex: poor TV signals).
Sharpness adjustment can be chosen to be coarse or fine.
It is recommended to use the default values.
Advanced Data settings
The advanced button enables the advanced settings for a data source.
R5976491 IQ PRO G500 01/02/2007
99