Barco R9040100 Projector User Manual


 
Service Mode
9-3
5976069 BARCOREALITY SIM6 21032000
Start Up
1 Push the cursor key é or ê to highlight 'Title Page' (menu 1).
2 Press Enter to select.
The Title page will be displayed.
Select with é or ê
then <ENTER>
<EXIT> to return.
menu 1
Select with é or ê
then <ENTER>
<EXIT> to return.
BARCO
REALITY SIM6
Proj. address : 001
Soft. version : 1.0
Config : front/
ceiling
Baudrate PC : 9600
text : ON
Serial no.: 1010200
Run time : 100 h
IDENTIFICATION
TITLE PAGE
SIM OPTIONS
Available items
-
type
of projector : BARCOREALITY SIM6
-
software version
-
Proj. Address
: to change the address of the projector, see Change Projector Address in this chapter.
-
Installation
: possible installations :
* Front/Ceiling
* Front/Table
* Rear/Ceiling
* Rear/Table
To change the installation configuration follow the instructions in chapter Installation Guidelines.
-
Baud rate
: transfer speed for communication with an IBM PC (or compatible) or MAC. The baud rate of the projector must be
the same as the baud rate of the connected computer. When there is a difference, consult 'Change Baudrate PC' in this chapter.
-
Projector Run Time
: gives the total run time since the first start up. All projectors leave the factory with a run time of approximately
24 hours.
-
Projector Serial number
: indicates the fabrication number of the projector. This number can be useful when calling for technical
assistance.
SIM Options
What will be indicate ?
This menu will indicate if the SIM options are installed or not.
Start Up
1 Push the cursor key é or ê to highlight 'SIM Options' (menu 1).
2 Press Enter to select.
The SIM options screen will be displayed (menu 2).
menu 2
Select with é or ê
then <ENTER>
<EXIT> to return.
menu 1
IDENTIFICATION
TITLE PAGE
SIM OPTIONS
<EXIT> to return.
menu 2
SIM OPTIONS
SOFT EDGE: ON
TDR : ON
TMR : ON
UNIFORMITY : ON
MOT. DIMMING : ON
Available SIM options
- Soft Edge
- TDR : transportation delay reduction
- TMR : true motion reproduction
- Uniformity
- Motorized Dimming