Black Box TS1002A Barcode Reader User Manual


 
70
OMNISCANNER
OMNIScanner2 only: Press ENTER to change the Destination: from MMC
(MultiMediaCard™) to Internal. Use the up-arrow and down-arrow keys to
highlight the desired destination and press ENTER to select it as the default
destination. Select MMC if you want to collect test results on the MultiMediaCard.
(See Chapter 11, MultiMediaCard for more information about MMC.) Select
Internal if you want to save the results to OMNIScanner’s internal memory. In
either case, results can be transferred to the Scanlink Tools software program. (See
Chapter 9, Uploading and Printing, for more information.)
In the Save Graph Options section, you will be able to define which of the
graphs will be saved.
If a checkbox is checked , OMNIScanner will store an Autotest with the
graph information for that particular test.
NOTE
Saving graphs reduces the number of Autotests that can be stored.
Depending on the performed Autotest, NEXT/PSNEXT, ELFEXT/PSELFEXT,
Return Loss, and Attenuation graphs can be saved.
Use the up-arrow and down-arrow keys to highlight the Save Graph Option
checkboxes.
Press to select the graph to be saved.
Press (Save) to save your changes and return to the SETUP screen.
Press ESC to discard the changes and return to the SETUP screen.