Cambridge SoundWorks P460 Switch User Manual


 
Chapter 2 Avaya P460 CLI Commands
Avaya P460 Reference Guide 129
The syntax for this command is:
show environment power
Example:
show event-log
User level: read-only, read-write, admin.
Displays the encrypted event log file.
The syntax for this command is:
show event-log
show event-log (Layer 3)
User level: read-only, read-write, admin.
Displays the encrypted event log file.
The syntax for this command is:
show event log
P460 > show environment power
PSU1 Capacity: 300 Watts (48V @ 6.25 Amps)
PSU2 Capacity: none
PSU3 Capacity: none
PSUs Configuration: 1 PSU/s , no redundancy.
Total Power Available: 300 Watts (6.25 Amps @ 48V)
Total Power drawn from the system: 238 Watts (4.95 Amps @ 48V)
Remaining Power in the system: 62 Watts (1.29 Amps @ 48V)
Slot Card-Type Active Enabled Draws(W)
Fault
---- -------------------- ------- ------- ---------
-----
3NY0
4 avayaP460-M4648ML-T Y Y 48
5NY0
6NY0
*- 2 SPVs power consumption: 70(W) x 2, Fans power consumption: 50(W)