GAMMA
Gamma adjustment
Format
GAMMA=<Gamma adjustment:Number>
GET□GAMMA / ?△GAMMA
Setting values for <Gamma adjustment: Number> are -10 to 10.
Environment
Power Input
OFF ON PM D-RGB A-RGB1 A-RGB2 COMP VIDEO HDMI None
X O X -
Response
"i:OK" is returned if the parameter was set properly.
For '
GET GAMMA' or '?GAMMA', current gamma adjustment is returned as
'
g:GAMMA=<Gamma adjustment:Number>'
For details on other responses, refer to the "Error List".
Description
(1) This performs the Gamma adjustment.
(2) This command functions in the same way as when "Image adjustment" - "Gamma adjustment"
are selected on the menu.
(3) If numerical parameters are outside the range, "e:0801 INVALID_VALUE" is returned.
(4) This sets the currently selected input signal and image mode.
(5) The current gamma adjustment can be acquired using the applicable GET command. ("
GET
GAMMA
")
Example
Setting
> GAMMA=-1 This sets the gamma correction to –1.
< i:OK
Reference
> GET GAMMA or ?GAMMA This retrieves the gamma adjustment.
< g:GAMMA=3
* Commands are indicated by ">", and responses are indicated by "<".