Projector WUX10 MarkII User Commands
- 74 -
Revision Histor
y
/ Date Chan
g
es Revised b
y
A
pp
roved b
y
TMPL
Temperature limit inquiry
Format
GET□TMPL
<n>
Number 0 to 255
<v>
Temperature value 0.0 to 127.9 °C
Environment
Power Input
OFF ON PM D-RGB A-RGB1 A-RGB2 COMP VIDEO HDMI None
X O X -
Response
Private commands (disclosed upon request)
Temperature limit is returned as '
g:TMPL=<n>{,<v>}'
For details on other responses, refer to the "Error List".
Description
(1) This returns the limit value (of machine-stoppage) of each temperature sensors.
(2) Number of temperature sensors varies according to model.
(3) When returning multiple temperature sensor values, values will be separated with a comma.
There are cases when a number of sensors is 0. In this case, there will not be a comma.
(4) For correspondence of temperature sensor sequence and actual installation location, inquire
separately.
Example
Setting
None
Reference
> GET TMPL This retrieves the temperature sensor limit values.
< g:TMPL=5,71.0,90.0,57.0,44.0,53.0
* Commands are indicated by ">", and responses are indicated by "<".