Canon WUX10 Projector User Manual


 
Projector WUX10 MarkII User Commands
- 75 -
Revision Histor
y
/ Date Chan
g
es Revised b
y
A
pp
roved b
y
TRACK
Tracking adjustment
Format
TRACK=<Adjustment value:Number>
GETTRACK / ?TRACK
Environment
Power Input
OFF ON PM D-RGB A-RGB1 A-RGB2 COMP VIDEO HDMI None
X O X X O O X X X X
Response
"i:OK" is returned if the parameter was set properly.
For '
GET TRACK' or '?TRACK', current tracking adjustment value is returned as
'
g:TRACK=<Adjustment value:Number>'
For details on other responses, refer to the "Error List".
Description
(1) This is used for adjustment when tracking (synchronization) is out of sync and the screen
flickers.
(2) This command functions in the same way as when "Display setting" - "Input signal selection" -
"Tracking adjustment" are selected on the menu.
(3) If the input is neither "A-RGB1" nor "A-RGB2", 'e:200X INVALID_SOURCE(***)' is returned
as an error response.
(4) If signals are not input, 'e:2010 NO_SIGNAL' is returned.
(5) Adjustment range is limited. If number is invalid, "e:0801 INVALID_VALUE" is returned.
(6) The GET command can be used to retrieve the current tracking adjustment values. ("
GET
TRACK
")
Example
Setting
> TRACK=25 The tracking adjustment value is set to 25.
< i:OK
Reference
> GET TRACK or ?TRACK This retrieves the tracking adjustment setting value.
< g:TRACK=21
* Commands are indicated by ">", and responses are indicated by "<".