Canon WUX10 Projector User Manual


 
Projector WUX10 MarkII User Commands
- 3 -
Revision Histor
y
/ Date Chan
g
es Revised b
y
A
pp
roved b
y
Communication System (Serial)
Item Specifications
Communication system RS-232-C Start-stop synchronization Semi-duplex communication
Transmission speed 19.2 Kbps
Character length 8 bits/character
Stop bit 2 bits
Parity None
Transmission format Variable-length record with terminal as delimiter
Maximum transmission
length
Maximum of 256 characters (bytes) including delimiters.
Delimiters are one of CR, LF, CR+LF, Null (0) (delimiters are identified
automatically).
Delimiters
Response delimiters are identical to command delimiters.
ASCII code (General-purpose characters: 20h to 7Fh), Tab (09h)
(Codes other than those above and delimiters are considered other
separator codes)
Uppercase and lowercase of alphabetic characters are considered the same
character.
Transmission codes
Double-byte characters and single-byte characters are not distinguished. All
are considered single-byte characters.
Communication
procedure
No procedure
Flow control None
Error control None
Break signal Not supported
Tc Character 5s (Timeout between CR and LF is 10ms.)
Time out
Tr
Command/response
interval:
15s
Communication System (LAN)
Item Specifications
Communication system
Transmission speed
Character length