30-25
Cisco ASA Series Firewall ASDM Configuration Guide
Chapter 30 Configuring the ASA CX Module
Managing the ASA CX Module
Detailed Steps
Shutting Down the Module
Shutting down the module software prepares the module to be safely powered off without losing
configuration data. Note: If you reload the ASA, the module is not automatically shut down, so we
recommend shutting down the module before reloading the ASA. To gracefully shut down the module,
perform the following steps at the ASA CLI.
Guidelines
In multiple context mode, perform this procedure in the system execution space.
Detailed Steps
Command Purpose
For a hardware module (ASA 5585-X):
hw-module module 1 reload
For a software module (ASA 5512-X through
ASA 5555-X):
sw-module module cxsc reload
Example:
ciscoasa# hw-module module 1 reload
Reloads the module software.
For a hardware module:
hw-module module 1 reset
For a software module:
sw-module module cxsc reset
Example:
ciscoasa# hw-module module 1 reset
Performs a reset, and then reloads the module.
Command Purpose
For a hardware module (ASA 5585-X):
hw-module module 1 shutdown
For a software module (ASA 5512-X through
ASA 5555-X):
sw-module module cxsc shutdown
Example:
ciscoasa# hw-module module 1 shutdown
Shuts down the module.