Cisco Systems OL-1089-11 Network Hardware User Manual


 
1-117
Cisco Media Gateway Controller Software Release 9 Billing Interface Guide
OL-1089-11
Chapter 1 Billing Interfaces
CDE Detail Description
Scale Factor (Tag: 4062)
Test Line Indicator (Tag: 4063)
Table 1-109 Scale Factor Description Form
Name: Scale Factor Tag: 4062 Source: MDL/Engine
Description/Purpose: Used for reporting Advice of Charge information.
Format: BE Length in Octets: 4
Data Value: The actual value for the scale factor is given by 10^x, where x is the value of the scale factor. The coding of scale
factor is as follows; all other values are spare:
— (249) –7 0.0000001
— (250) –6 0.000001
— (251) –5 0.00001
— (252) –4 0.0001
— (253) –3 0.001
— (254) –2 0.01
— (255) –1 0.1
— 0 1
— 1 10
2 100
3 1000
Extended Data Value: No extended value.
General Information:
MGC Release: Release 9 and later.
Table 1-110 Test Line Indicator Description Form
Name: Test Line Indicator Tag: 4063 Source: MDL/Engine
Description/Purpose: The test line indicator is used for reporting the type of test line.
Format: BE Length in Octets: 4
Data Value: Valid values for the TestLineType integer are:
TYPE_100 = 0
TYPE_102 = 1
TYPE_105 = 2
TYPE_108 = 3
Extended Data Value: No extended value.
General Information:
MGC Release: Release 9 and later.