CDE Detail Description
User Service Information (Tag: 2001/ANSI)
Table 1-24 User Service Information Description Form
Name: User Service Information Tag: 2001 Source: MDL
Description/Purpose: This parameter is used to send the data transmission parameters to the distant exchange. The field
format is the same as the format for the bearer capability information element from ANSI standard T1.607.
Format: ANSI T1.113 Length in Octets: 2 to 13
Data Value: For more detail, please refer to ANSI T1.113.
Extension: octet continues through the next octet, 1 last octet
Coding standard: the setting should be 00 for CCITT standard, 10 for national
Information Transfer Capability. For POTS calling, this field is set at one of the following:
00000 Speech
01000 Unrestricted digital information
01001 Restricted digital information
10000 3.1 kHz audio
10001 Unrestricted digital information with tone and announcements
Transfer Mode (octet 2)
00 Circuit mode
10 Packet mode
7.3 Information Transfer Rate
00000 Packet mode only
10000 64 kb
00011 384 kb
10100 1472 kb
10101 1536 kb
10111 1920 kb
11000 Multi-rate
Structure, Configuration, Establishment, and so on: please refer to T1.113
Extended Data Value: No extended value.
General Information: