I-2 POST Error Messages
Writer: Rickard Project: Compaq Smart Array 3200 Controller Reference Guide Comments: 340862-002
File Name: P-APPI.DOC Last Saved On: 12/7/98 9:35 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
POST Error Messages
continued
Code Meaning Recommended Action
1723 Slot x Drive Array - To improve signal
integrity, internal SCSI connector should be
removed if external drives are attached to the
same SCSI port (followed by one of the
following instructions:)
1. Please detach internal SCSI Port Interface
Board from Smart Array 3200 Controller.
2. Please replace Dual-Connector Internal
SCSI Port Interface Board with Single-
Connector Internal SCSI Port Interface Board.
3. Please replace Dual-Connector Internal
SCSI Port Interface Board with Single-
Connector Internal SCSI Port Interface Board
and move external SCSI cable to Port 2 (with
system power OFF.
4. Please turn system power OFF and move
external SCSI cable to Port 2.
5. Please detach or replace Dual-Connector
Internal SCSI Port Interface Board with Single-
Connector SCSI Port.
With system power off, remove or replace the
connector daughterboard and/or external cables
attached to the Smart Array 3200 Controller
board as instructed.
1724 Slot x Drive Array - Physical Drive Position
Changes(S) Detected - Logical drive
configuration has automatically been
updated.
This message indicates that logical drive
configuration has been updated automatically
following physical drive position changes. Press
F1 to resume.
1726 Slot x Drive Array - Array Accelerator Memory
Size Change Detected.
This message indicates that the array
accelerator configuration has been updated
automatically due to replacement of the Array
Accelerator (or controller) with one of them
having different memory size. Press F1 to
resume.
continued