Figure 2-5. Failed arrays removed; arrays on separate controllers
To restore an array to its original controller, make sure the conditions for
moving drives are met. Then:
IMPORTANT: These steps must be followed AS DESCRIBED. Any deviation
or mistake could result in the loss of all data across all moved arrays.
1. Power-down the system.
2. Move the array back to its original controller but retain its drive position
from the consolidated configuration.
3. Power-up the system.
4. Each controller will indicate a 1789 POST message, “Drives are
Missing.” Press F2 to fail the missing drives.
5. Run the Array Configuration Utility and remove the appropriate failed
arrays.
6. Reboot the system.