I-11
Compaq Smart Array 3200 Controller Reference Guide
Writer: Rickard Project: Compaq Smart Array 3200 Controller Reference Guide Comments: 340862-002
File Name: P-APPI.DOC Last Saved On: 12/7/98 9:35 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
POST Error Messages
continued
Code Meaning Recommended Action
1792 Slot x Valid Data Found in Array Accelerator.
Data automatically written to drive array.
While the system was in use, power was
interrupted or the system was restarted while
data was in the Array Accelerator memory.
Power was then restored within four days, and
data in the Array Accelerator was flushed to the
drive array.
1793 Slot x Drive Array - Array Accelerator Battery
Depleted. Data in Array Accelerator has been
lost. (Error message 1794 also displays.)
While the system was in use, power was
interrupted while data was in the Array
Accelerator memory. Power was not restored
within four days, and data in the Array
Accelerator was lost. Check all files for potential
data corruption.
-Or-
The Array Accelerator batteries have failed.
1794 Slot x Drive Array - Array Accelerator Battery
Charge Low. Array Accelerator is temporarily
disabled. Array Accelerator will be re-enabled
when battery reaches full charge.
The battery charge is below 90%. Posted writes
are disabled. When the batteries are fully
charged, the Array Accelerator will automatically
be re-enabled and this POST message will be
discontinued. Replace the Array Accelerator or
the Smart Array Controller if batteries do not
recharge within 36 power-on hours.
1795 Slot x Drive Array - Array Accelerator
Configuration Error. Data does not correspond
to this drive array. Array Accelerator is
temporarily disabled.
The data stored in the Array Accelerator does
not correspond to this drive array. Match the
Array Accelerator to the correct drive array.
-Or-
Run the Compaq System Configuration Utility to
clear data in the Array Accelerator.
Continued