I-7
Compaq Smart Array 3200 Controller Reference Guide
Writer: Rickard Project: Compaq Smart Array 3200 Controller Reference Guide Comments: 340862-002
File Name: P-APPI.DOC Last Saved On: 12/7/98 9:35 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
POST Error Messages
continued
Code Meaning Recommended Action
1776 Slot x Drive Array - SCSI Port (y) Termination
Problem Detected.
(RESUME = F1 KEY)
The termination power signal for the specified
SCSI port was shorted to ground. Termination
power was automatically turned off to prevent
damage to the internal hardware.
Turn off the server power and check the cabling
to the specified SCSI port. Replace damaged
cables/faulty SCSI devices attached to cable.
1777 Slot x Drive Array - ProLiant Drive Storage
System Problem Detected (followed by one or
more of the following):
SCSI Port (y): Cooling Fan Malfunction
Detected
SCSI Port (y): Overheated Condition
Detected
SCSI Port (y): Sidepanel must be Closed
to Prevent Overheating
SCSI Port (y): Redundant Power Supply
Malfunction Detected
SCSI Port (y): Wide SCSI Transfer Failed
SCSI Port (y): Interrupt
(RESUME = F1 KEY)
Check cooling fan operation by placing hand
over fan. Check internal plenum cooling fan in
tower servers or storage systems. If fan is not
operating, check for obstructions and check all
internal connectors. Replace unit side panel if
removed.
If the ProLiant Storage System power LED is
amber instead of green, this indicates a
redundant power supply failure.
Check SCSI cables. Note that Port 1 refers to the
“internal” SCSI bus, and Port 2 refers to the
“external” SCSI bus. If the message indicates to
check SCSI cables, refer to cabling information
in the
Smart Array 3200 Controller Installation
Guide
.
1778 Slot x Drive Array resuming Automatic Data
Recovery process
No action is required. This message appears
when a controller resets or a power cycle
occurs while Automatic Data Recovery is in
progress.
Continued