Dell 28XX Switch User Manual


 
28 Dell PowerConnect 28xx Systems User Guide
Site Requirements
The PowerConnect 28xx can be mounted in a standard equipment rack, placed on a tabletop, or
mounted on the wall.
Before installing the device, verify that the site selected for the device meets the following site
requirements:
Power
— The device is installed within 1.5 m (5 feet) of a grounded, easily accessible outlet 220/110
VAC, 50/60 Hz. If the device has two power supplies, the site should have two power outlets with
different power feeders.
General
— Ensure that the power supply is correctly installed.
Clearance
— There is adequate frontal clearance for operator access. Allow clearance for cabling,
power connections, and ventilation.
Cabling
— Cabling is routed to avoid sources of electrical noise such as radio transmitters, broadcast
amplifiers, power lines, and fluorescent lighting fixtures.
Ambient Requirements
— The ambient device operating temperature range is 0 to 45 °C (32 to
113 °F) at a relative humidity of up to 95%, non-condensing. Verify that water or moisture cannot enter
the device case.
Unpacking
Package Contents
While unpacking the device, ensure that the following items are included:
•The device
AC power cable
Self-adhesive rubber pads (for on-shelf installation)
Rack-mount kit for installation
Documentation CD
Product Information Guide
Unpacking the Device
To unpack the PowerConnect device:
NOTE: Before unpacking the device, inspect the packaging and report any evidence of damage.
1
Place the box on a clean flat surface.
2
Open the box or remove the box top.
3
Carefully remove the device from the package and place it on a secure, stable and clean surface.
4
Remove all packing material.