Dell 34XX Computer Accessories User Manual


 
Configuring System Information 155
The
Optical Transceiver
page contains the following fields:
Port
— The port IP address on which the cable is tested.
Temperature
— The temperature (C) at which the cable is operating.
Voltage
— The voltage at which the cable is operating.
Current
— The current at which the cable is operating.
Output Power
— The rate at which the output power is transmitted.
Input Power
— The rate at which the input power is transmitted.
Transmitter Fault
— Indicates if a fault occurred during transmission.
Loss of Signal
— Indicates if a signal loss occurred in the cable.
Data Ready
— The transceiver has achieved power up and data is ready.
Displaying the Optical Transceiver Diagnostics Test Results Table
1
Open the
Optical Transceiver
page.
2
Click
Show All
.
The test runs and the
Optical Transceiver Diagnostics Table
page opens.
In addition to the fields in the
Optical Transceiver
page
,
the
Optical Transceiver Diagnostics Table
contains the following field:
Unit No
. — The unit number for which the cable is displayed.
N/A
— Not Available, N/S - Not Supported, W - Warning, E - Error
NOTE: Finisar transceivers do not support transmitter fault diagnostic testing.
NOTE: Fiber Optic analysis feature works only on SFPs that support the digital diagnostic standard
SFF-872.
Performing Fiber Optic Cable Tests Using CLI Commands
The following table contains the CLI command for performing fiber optic cable tests.
Table 6-38. Fiber Optic Cable Test CLI Commands
CLI Command Description
show fiber-ports optical-
transceiver [
interface
]
[
detailed
]
Displays the optical transceiver
diagnostics.