(C15, C16, C17). If the data length is out of this range, i.e. occupy other addresses except C0~C17, an
error may occur.
6) The effective addresses of Cn are not consecutive (5 blocks: C0~17, C40~41, C45~C48, C50,
C90~C92). However, when executing duplicate function (Decrease Address), the addresses will be
regarded as consecutive addresses. For example, the next address of C90 is C50; the next address of
C50 is C48; the next address of C45 is C41; the next address of C40 is C17.
7) When all Word address is written, the controllers all response ACK(0x06). But when all Word address is
read, the receive value will not change. The user needs to press ACT_DATA0 again and then the
receive value will be updated.