Join Timer— Indicates the amount of time, in centiseconds, that PDUs are transmitted. The default value is
20 centiseconds.
Leave Timer— Indicates the amount of time lapse, in centiseconds, that the device waits before leaving its
GARP state. Leave time is activated by a Leave All Time message sent/received, and cancelled by the Join
message received. Leave time must be greater than or equal to three times the join time. The default value is
60 centiseconds.
Leave All Timer — Indicates the amount of time lapse, in centiseconds, that all device waits before leaving
the GARP state. The leave all time must be greater than the leave time. The default value is 1000 centisec-
onds.
2. Click . The GARP Parameters Settings Page opens:
Figure 67: GARP Parameters Settings Page
3. Modify the Interface, Join Timer (centiseconds), Leave TImer (centiseconds), and Leave All Timer (centisec-
onds) fields.
4. Click . The GARP parameters are defined, and the device is updated.