Epson S1F70000 Power Supply User Manual


 
S1F70000 SeriesEPSON5–7
Technical Manual
S1F77200Y Series
S1F77200Y
Series
S1F77210Y1S0
(Ta = –30°C to +85°C is assumed except where otherwise specified.)
Parameter Symbol Conditions (V
SS = 0.0V) Min. Typ. Max. Unit
Operating voltage VDD 1.50 12.0 V
Detection voltage VDET Ta = 25°C 2.30 2.35 2.40 V
Hysteresis width VHYS VHYS = VREL – VDET 0.05 0.10 0.15 V
Operating current IDD VDD = 3.0V 2.00 5.00 µA
Detection voltage VDET
–300 –100 +100 ppm/°C
temperature characteristics V
DET
High level output current IOH
VDD = 3.0V
–1.00 –0.25 mA
OUT = 2.7V
Low level output current IOL
VDD = 2.0V
0.20 1.00 mA
OUT = 0.2V
VDD = 3V2V
—840 µs
Detection voltage
T
PHL
Ta = 25°C
response time
V
DD = 3V2V
200 µs
Ta = –30°C to +85°C
S1F77210Y1E0
(Ta = –30°C to +85°C is assumed except where otherwise specified.)
Parameter Symbol Conditions (V
SS = 0.0V) Min. Typ. Max. Unit
Operating voltage VDD 1.50 12.0 V
Detection voltage VDET Ta = 25°C 2.50 2.55 2.60 V
Hysteresis width VHYS VHYS = VREL – VDET 0.05 0.10 0.15 V
Operating current IDD VDD = 3.0V 2.00 5.00 µA
Detection voltage VDET
–300 –100 +100 ppm/°C
temperature characteristics V
DET
High level output current IOH
VDD = 3.0V
–1.00 –0.25 mA
OUT = 2.7V
Low level output current IOL
VDD = 2.0V
0.20 1.00 mA
OUT = 0.2V
VDD = 3V2V
—840 µs
Detection voltage
T
PHL
Ta = 25°C
response time
V
DD = 3V2V
200 µs
Ta = –30°C to +85°C