Epson S1F70000 Power Supply User Manual


 
S1F77200Y Series
5–18EPSONS1F70000 Series
Technical Manual
S1F77200Y1V0
(Ta = –30°C to +85°C is assumed except where otherwise specified.)
Parameter Symbol Conditions (V
SS = 0.0V) Min. Typ. Max. Unit
Operating voltage VDD 0.80 10.0 V
Detection voltage VDET Ta = 25°C 0.90 0.95 1.00 V
Hysteresis width VHYS VHYS = VREL – VDET 0.03 0.05 0.08 V
Operating current IDD VDD = 1.5V 1.50 4.00 µA
Detection voltage VDET
–300 –100 +100 ppm/°C
temperature characteristics V
DET
Low level output current IOL
VDD = 0.8V
0.05 0.40 mA
OUT = 0.16V
VDD = 1.5V0.8V
—840 µs
Detection voltage
T
PHL
Ta = 25°C
response time
V
DD = 1.5V0.8V
200 µs
Ta = –30°C to +85°C
S1F77220Y2D0
(Ta = –30°C to +85°C is assumed except where otherwise specified.)
Parameter Symbol Conditions (V
SS = 0.0V) Min. Typ. Max. Unit
Operating voltage VDD 1.5 12.0 V
Detection voltage VDET Ta = 25°C 1.20 1.25 1.30 V
Hysteresis width VHYS VHYS = VREL – VDET 0.03 0.05 0.08 V
Operating current IDD VDD = 3.0V 1.50 4.00 µA
Detection voltage VDET
–300 –100 +100 ppm/°C
temperature characteristics V
DET
Low level output current IOL
VDD = 1.5V
–0.03 –0.06 mA
OUT = 0.64V
VDD = 1.5V0.8V
—840 µs
Detection voltage
T
PHL
Ta = 25°C
response time
V
DD = 1.5V0.8V
200 µs
Ta = –30°C to +85°C