Epson S1F70000 Power Supply User Manual


 
S1F77200Y Series
5–12EPSONS1F70000 Series
Technical Manual
S1F77210Y120
(Ta = –30°C to +85°C is assumed except where otherwise specified.)
Parameter Symbol Conditions (V
SS = 0.0V) Min. Typ. Max. Unit
Operating voltage VDD 1.50 12.0 V
Detection voltage VDET Ta = 25°C 4.50 4.60 4.70 V
Hysteresis width VHYS VHYS = VREL – VDET 0.08 0.15 0.22 V
Operating current IDD VDD = 5.0V 2.00 5.00 µA
Detection voltage VDET
–300 –100 +100 ppm/°C
temperature characteristics V
DET
High level output current IOH
VDD = 5.0V
–2.00 –0.50 mA
OUT = 4.5V
Low level output current IOL
VDD = 2.0V
0.20 1.00 mA
OUT = 0.2V
VDD = 5V4V
—840 µs
Detection voltage
T
PHL
Ta = 25°C
response time
V
DD = 5V4V
200 µs
Ta = –30°C to +85°C
S1F77210Y1K0
(Ta = –30°C to +85°C is assumed except where otherwise specified.)
Parameter Symbol Conditions (V
SS = 0.0V) Min. Typ. Max. Unit
Operating voltage VDD 1.50 12.0 V
Detection voltage VDET Ta = 25°C 4.70 4.80 4.90 V
Hysteresis width VHYS VHYS = VREL – VDET 0.13 0.20 0.27 V
Operating current IDD VDD = 5.0V 2.00 5.00 µA
Detection voltage VDET
–300 –100 +100 ppm/°C
temperature characteristics V
DET
High level output current IOH
VDD = 5.0V
–2.00 –0.50 mA
OUT = 4.5V
Low level output current IOL
VDD = 2.0V
0.20 1.00 mA
OUT = 0.2V
VDD = 5V4V
—840 µs
Detection voltage
T
PHL
Ta = 25°C
response time
V
DD = 5V4V
200 µs
Ta = –30°C to +85°C