Krautkramer USN 52R/USN 52L Issue 05, 02/00 9-5
DGS evaluation (option) 13 fixed-programmed probes, one probe user-definable; sound attenuation correction
for reference block and test object, transfer correction and quadrant echo correction
(for angle probes), reference reflectors: backwall, side drilled hole or circular disk
Storage temperature From -40 °C to +75 °C
Operating temperature From 0 °C to + 55 °C
Interface RS 232 C, bidirectional for data transfer to a serial printer (EPSON format) or to a
PC, or remote control of all settings from the PC
Analog output 5V TTL switching voltage with gate alarm
0V to 2.5V analog voltage proportional to the echo amplitude
0V to 2.5V analog voltage proportional to the sound path of an echo in the gate
Battery mode 6 AlMn or NiCad batteries (D-size)
Operation period with fully charged NiCd batteries (5 Ah):
USN 52R: 5.5 hours
USN 52L: 10 hours
Probe connectors BNC or LEMO
Weight 2.7 kg including batteries
Dimensions 250 mm x 133 mm x 146 mm (W x D x H)
Specifications
Krautkramer USN 52R/USN 52L Issue 05, 02/00 9-5
DGS evaluation (option) 13 fixed-programmed probes, one probe user-definable; sound attenuation correction
for reference block and test object, transfer correction and quadrant echo correction
(for angle probes), reference reflectors: backwall, side drilled hole or circular disk
Storage temperature From -40 °C to +75 °C
Operating temperature From 0 °C to + 55 °C
Interface RS 232 C, bidirectional for data transfer to a serial printer (EPSON format) or to a
PC, or remote control of all settings from the PC
Analog output 5V TTL switching voltage with gate alarm
0V to 2.5V analog voltage proportional to the echo amplitude
0V to 2.5V analog voltage proportional to the sound path of an echo in the gate
Battery mode 6 AlMn or NiCad batteries (D-size)
Operation period with fully charged NiCd batteries (5 Ah):
USN 52R: 5.5 hours
USN 52L: 10 hours
Probe connectors BNC or LEMO
Weight 2.7 kg including batteries
Dimensions 250 mm x 133 mm x 146 mm (W x D x H)
Specifications