Epson USN 52L Printer User Manual


 
Krautkramer USN 52R/USN 52L Issue 05, 02/00 1-9
2-stage adjustment of pulse repetition rate in order to
avoid phantom echoes,
indication of amplitude and sound path for flaw
testing and thickness measurement,
DAC for convenient display evaluation according to
the reference block method (e.g. ASME code, etc.),
analog outputs for external control purposes: propor-
tional voltage for amplitude and sound path of the
echo in the monitor gate,
A-scan storage, peak freeze and zoom function,
preview of all stored A-Scans,
locking function to avoid unintentional alteration of
set values,
magnified display of measured values for easy
reading even from longer distances,
rapid switching between programmable sound
velocities, e.g. for longitudinal and transverse waves
in steel.
60 Hz A-scan refresh rate,
mains power or battery operation (max. 5 hours of
operation),
on-board Data Logger for storage of up to 2,500
thickness readings in a maximum of 99 freely
configurable files,
RS232 interface for data transfer, A-scan displays
and reports, or for remote control of the USN 52 R,
storage of 140 (USN 52R) / 100 (USN 52L) control
data sets enabling quick calibration and reproducibil-
ity of the test,
alphanumeric entry of data set names and display of
a directory of all data sets,
frequency ranges from 0.25 - 11 MHz wide band
echo representation: RF signal, full-wave, positive
and negative half-wave,
optimized probe matching by means of 4 adjustable
damping values between 50 and 1000 ohms,
automatic calibration of the sound velocity and probe
delay according to data from 2 calibration echoes
(with plausibility check),
USN 52R/USN 52L
Introduction
Krautkramer USN 52R/USN 52L Issue 05, 02/00 1-9
2-stage adjustment of pulse repetition rate in order to
avoid phantom echoes,
indication of amplitude and sound path for flaw
testing and thickness measurement,
DAC for convenient display evaluation according to
the reference block method (e.g. ASME code, etc.),
analog outputs for external control purposes: propor-
tional voltage for amplitude and sound path of the
echo in the monitor gate,
A-scan storage, peak freeze and zoom function,
preview of all stored A-Scans,
locking function to avoid unintentional alteration of
set values,
magnified display of measured values for easy
reading even from longer distances,
rapid switching between programmable sound
velocities, e.g. for longitudinal and transverse waves
in steel.
60 Hz A-scan refresh rate,
mains power or battery operation (max. 5 hours of
operation),
on-board Data Logger for storage of up to 2,500
thickness readings in a maximum of 99 freely
configurable files,
RS232 interface for data transfer, A-scan displays
and reports, or for remote control of the USN 52 R,
storage of 140 (USN 52R) / 100 (USN 52L) control
data sets enabling quick calibration and reproducibil-
ity of the test,
alphanumeric entry of data set names and display of
a directory of all data sets,
frequency ranges from 0.25 - 11 MHz wide band
echo representation: RF signal, full-wave, positive
and negative half-wave,
optimized probe matching by means of 4 adjustable
damping values between 50 and 1000 ohms,
automatic calibration of the sound velocity and probe
delay according to data from 2 calibration echoes
(with plausibility check),
USN 52R/USN 52L