DTC SELECTION: byte 3E
If reserved value is specified, this scanner returns the following error information as follows:
- Status: B’00001’ (CHECK CONDITION)
- Sense key: X’5’ (ILLEGAL REQUEST)
Note:
If simplified dynamic threshold is selected. (Byte 3E=X'00' or X'80'), variance rate (byte 2E)
is valid.
If dynamic threshold is selected (byte 3E=X'40'), DTC mode (byte 2F and 30) are valid.
Byte 3E
DTC SELECTION BYTE
Reserved
b5
Reserved
DTC SELECTION
00: Default; Simplified DTC, if IPC-2D or IPC-3D optioned.
01: Dynamic threshold
10: Simplified DTC, if IPC-2D or IPC-3D optioned.
11: Reserved
b7
b6
b2
b4
b3
b1
b0