Image Functions
3-6
Figure 3.2 The window position and limitation of ADF reading
The Matrix size of the clipped Main Window is limited as shown in Figure 3.3. The unit of the
number in Figure 3.3 is 1/1200 in.
14592 (@ 1/1200 in.) = 12.16 in. (308.8 mm)
19842 (@ 1/1200 in.) = 16.54 in. (412.0 mm)
20736 (@ 1/1200 in.) = 1728 in. (438.9 mm)
X
1
W
ULX
ULY
L
Origin point of
the clipped area
Feed direction
13200 (@ 1/1200 in.)
= 11 in. (279.4 mm)