Fujitsu M3097DG Scanner User Manual


 
A.4 Commands
Appendix A-81
A.4.10 SEND command
The following table shows the normal sequence of the SEND command when used with this
scanner.
Step Bus phase Initiator operation
Target operation
1 BUS FREE Verifies bus free
2 ARBITRATION
Obtains bus-usage
right
3 SELECTION Selects target
Drives BSY signal
4 MESSAGE OUT Selects logical unit
5 COMMAND
Specifies SEND
(CDB)
6 DATA OUT
Transfer data
7 STATUS
Reports GOOD status
8 MESSAGE IN
Reports Command Complete
Releases BSY signal
9 BUS FREE