Fujitsu M3097DG Scanner User Manual


 
Specifications
2-4
2.4 Physical specifications
Table 2.5 Physical specifications
No. Item M3097DE/DG
Height 234 ( 9.2 in.)
Width 696 (27.4 in.)
1 Dimensions
(mm)
Depth 497 (19.6 in.)
2 Weight (Kg) 20 ( 44.2 lb)
Voltage (VAC)
100 to 120, 200 to 240 VAC ±10%
Phase Single
3 Power
requirements
Frequency 50/60 Hz +2% -4%
4 Power consumption (VA) 120
5 Heat capacity 78 kcal ( 312 BTU/H)
6 Surge current (A) 30
7 Momentary power failure 100 % 0.5 Hz
8 Leakage current (mA) 0.75 or less
9 Dielectric strength AC 1.5 KV or more for one minute or
more (between FG and AC lines)
10 AC line noise
Voltage 1.2 KV pulse duration 5 µs
Operating +5 to +3511
Temperature (°C)
Non operating -20 to +60
Operating 20 to 80 (No condensation)12 Relative humidity
(%)
Non operating 8 to 95 (No condensation)
Operating 0.213 Vibration (G)
Non operating 0.4
Operating 514 Indication
(degree)
Non operating 10
15 ESD (KV) 8 or more
Operating 53 or less (ISO DIS 9296)16 Acoustic noise
(dBA)
Non operating 40 or less (ISO DIS 9296)
2.5 Regulation conformity
Table 2.6 Regulation conformity
Item Conformed regulation Regulation mark on the
scanner
Remarks
UL 1950
CSA 22.2 950
Yes, CSA NRTL-C markSafety
EN60950 1992/A1:1993/A2:1993 Yes, GS mark by TUV
FCC Part15 Class A Yes
EN55022 1994 Class B EMI
EN50082-1 1992 Immunity
EN61000-3-2 1995 Harmonic emission
EMI
etc.
EN61000-3-3 1995
Yes, CE mark