Fujitsu V6.00 Server User Manual


 
ServerView Event Manager 129
Trap overview
5.3.15 RAID Adapter traps (Megaraid.mib)
MIB-OID: 1.3.6.1.4.1.16.1.1.200
This section lists RAID Adapter traps in alphabetical order.
Trap name ID Meaning Error class
rtBatteryMissing 9020 Adapter-%d: Battery
Module is missing.
informational
rtBattery
TemperatureHigh
9022 Adapter-%d: Battery
Module temperature
exceeded Danger
Threshold.
informational
rtBatteryVolatageLow 9021 Adapter-%d: Battery
Module voltage is low.
informational
rtCheck
ConditionStatus
9018 Adapter-%d, Channel-%d,
Target-%d: Command
completed with Sense_Key-
0x%x ASC-0x%x ASCQ-
0x%x.
informational
rtCheck
ConsistencyAborted
9010 Adapter-%d, Logical Drive-
%d: Check consistency
aborted by user.
informational
rtCheck
ConsistencyCompleted
9009 Adapter-%d, Logical Drive-
%d: Check Consistency
completed. No
inconsistencies found.
informational
rtCheck
ConsistencyFailed
9012 Adapter-%d, Logical Drive-
%d: Check consistency
failed.
informational
rtCheck
ConsistencyStarted
9008 Adapter-%d, Logical Drive-
%d: Check consistency
started.
informational
rtConfigUpdated 9001 Adapter-%d: A new
configuration has been
written.
informational
Table 38: RAID Adapter traps