Fujitsu V6.00 Server User Manual


 
30 ServerView Event Manager
iRMC S2 SEL Entries and SC2 MIB Traps
3.7 iRMC S2 SEL entries relayed as SC2 MIB
traps
I The following table applies to PRIMERGY systems manufactured
in 2009 or later.
If the iRMC S2 writes an event to the System Event Log (SEL), in some cases
an SNMP trap is triggered. The following table shows the correlation between
the iRMC S2 entries in the SEL and the traps they trigger.
I Not all iRMC S2 entries made in the SEL trigger an SNMP trap. Some
trigger the same trap.
Error
code
iRMC S2 SEL entry Trap text Trap
no.
Trap name
000011 System event log
(SEL) warning
threshold exceeded
The System Event
Log for cabinet XY at
server XY has
exceeded XY
percent of its
capacity.
2101 sc2TrapMessa
geLogWarning
040000 ’FAN XY’: Fan failed Fan ’FAN XY’ failed
in cabinet XY of
server XY.
2014 sc2TrapFan
Failed
040001 ’FAN XY’: Fan is
working
Fan ’FAN XY’ was
added into cabinet
XY of server XY.
2010 sc2TrapFan
Added
Fan ’FAN XY’ in
cabinet XY of server
XY is working again.
2012 sc2TrapFanOk
040002 ’FAN XY’: Fan
prefailure
Fan ’FAN XY’ will fail
in near future in
cabinet XY of server
XY.
2013 sc2TrapFan
Critical
Table 4: iRMC S2 SEL entry - SC2 MIB trap