Fujitsu V6.00 Server User Manual


 
ServerView Event Manager 71
Making pager settings (COM port and modem)
You specify the pager service via the Pager, SMS-1 or SMS-2 tabs.
The Server Num tab tells you which server numbers are assigned to which server
name. The server number is sent to the pager type numeric.
You can test your settings by clicking the Test button.
For each service number, you make settings for data bits, parity and stop bits
and you define the prompt used by the pager service for messages.
With the SMS1 and SMS2 service, two services with different protocols can be
used to address a GSM mobile. SMS1 uses the TAP protocol, while SMS2 uses
the UCP protocol.
I If you have defined settings for the serial interfaces, you can define
whether an alarm is to trigger a call to a pager or mobile phone (see also
section "Forwarding alarms" on page 51).
Baud rate 2400 bps, 1200 bps or 300 bps
Data bits 8
Parity none
Stop bits 1
Dialling prefix ATDP0,01691
Table 12: Sample settings for the “Cityruf” pager service from Deutsche Telekom