32 ServerView Event Manager
iRMC S2 SEL Entries and SC2 MIB Traps
070001 ’PSU XY’: Power
supply OK
Power supply ’PSU
XY’ in cabinet XY at
server XY was
added.
2030 sc2TrapPower
SupplyAdded
Power supply ’PSU
XY’ in cabinet XY at
server XY is working
again.
2032 sc2TrapPower
SupplyOk
070002 ’PSU XY’: Power
supply failed
Power supply ’PSU
XY’ in cabinet XY at
server failed.
2034 sc2TrapPower
SupplyFailed
Redundant power
supply ’PSU XY’ in
cabinet XY at server
XY failed. System
can become critical
if another power
supply fails.
2035 sc2Trap
Redundant
PowerSupply
Failed
070003 ’PSU XY’: Redundant
power supply AC
failed
AC failure in cabinet
XY of server XY.
2040 sc2TrapAcFail
070005 Power unit: power
supply redundancy
lost
Power supply
redundancy in
cabinet XY at server
XY lost. System will
become critical if a
power supply fails.
2036 sc2TrapPower
Supply
Redundancy
Lost
070009 ’PSU XY’: Redundant
power supply DC
failed
DC power failure in
cabinet XY of server
XY.
2041 sc2TrapDcFail
070010 ’PSU XY’: Power
supply fan failure
Fan failure at power
supply ’PSU XY’ in
cabinet XY of server
XY.
2039 sc2TrapPower
SupplyFan
Failure
Error
code
iRMC S2 SEL entry Trap text Trap
no.
Trap name
Table 4: iRMC S2 SEL entry - SC2 MIB trap