Fujitsu V6.00 Server User Manual


 
142 ServerView Event Manager
Trap overview
sc2TrapMessageLogFul
l
2100 The System Event Log
(message log) is full. No
more messages can be
logged. This trap will not
occur on wrap-around log
types.
minor
sc2TrapMessageLogWa
rning
2101 The warning threshold for
the number of System
Event Log entries has been
exceeded.
minor
sc2TrapOnBattery 2042 The UPS is operating on
battery power or the power
supply is drawing current
from the backup battery unit
(BBU). This trap is
persistent and is resent at
one minute intervals until
the mains returns or the
system is switched off.
critical
sc2TrapOnMains 2043 The mains voltage returned
after a power failure.
informational
sc2TrapPowerOffTimeR
eached
2092 Power off time reached. informational
sc2TrapPowerSupplyAd
ded
2030 One hot-replace power
supply was added.
informational
sc2TrapPowerSupplyCri
tical
2033 Power supply status
became critical.
critical
sc2TrapPowerSupplyFai
led
2034 One hot-replace power
supply failed.
major
sc2TrapPowerSupplyOk 2032 Power supply is working
again.
informational
sc2TrapPowerSupplyRe
dundancyLost
2036 Power supply redundancy
id no longer available.
minor
sc2TrapPowerSupplyRe
moved
2031 One hot-replace power
supply was removed.
informational
Trap name ID Meaning Error class
Table 41: ServerControl traps (SC2.mib)