Fujitsu V6.00 Server User Manual


 
ServerView Event Manager 141
Trap overview
sc2TrapDcFail 2041 DC power failed in the
specified cabinet.
This is the result of the
systems power-good
sensor monitoring. The
system stops if this error
occurs.
critical
sc2TrapFanAdded 2010 The indicated hot-plug fan
was inserted.
informational
sc2TrapFanCritical 2013 The indicated fan became
critical.
major
sc2TrapFanFailed 2014 The indicated fan failed.
critical
sc2TrapFanOk 2012 The indicated fan is OK
again.
informational
sc2TrapFanRemoved 2011 The indicated hot-plug fan
was removed.
informational
sc2TrapIntrusionAsserti
on
2110 The front door or housing
was opened.
major
sc2TrapIntrusionChang
ed
2112 The front door or housing
was opened or closed.
major
sc2TrapIntrusionDeass
ertion
2111 The front door or housing
was closed.
informational
sc2TrapMemErrorModul
eFailing
2069 A memory module failed. major
sc2TrapMemErrorModul
ePrefail
2068 A memory module is
predicted to fail (prefailure).
major
sc2TrapMemErrorModul
eReplaced
2070 A memory module failed
and was replaced by a hot-
spare module.
major
Trap name ID Meaning Error class
Table 41: ServerControl traps (SC2.mib)