Fujitsu V6.00 Server User Manual


 
ServerView Event Manager 149
Trap overview
tapeAlertTrap12 12 You have tried to load a
cartridge of a type which is
not supported by this drive.
informational
tapeAlertTrap13 13 The operation has failed
because the tape in the
drive has snapped:
1. Discard the old tape.
2. Restart the operation
with a different tape.
critical
tapeAlertTrap14 14 The operation has failed
because the tape in the
drive has snapped:
1. Do not attempt to extract
the tape cartridge.
2. Call the tape drive
supplier helpline.
critical
tapeAlertTrap15 15 The memory in the tape
cartridge has failed, which
reduces performance. Do
not use the cartridge for
further backup operations.
minor
tapeAlertTrap16 16 The operation has failed
because the tape cartridge
was manually ejected while
the tape drive was actively
writing or reading.
critical
tapeAlertTrap17 17 You have loaded a cartridge
of a type that is read-only in
this drive. The cartridge will
appear as write-protected.
minor
tapeAlertTrap18 18 The directory on the tape
cartridge has been
corrupted. File search
performance will be
degraded.
minor
Trap name ID Meaning Error class
Table 44: Tape traps