136 ServerView Event Manager
Trap overview
sieScUserAuthentication
Failure
664 User authentication failure
is detected via PPP, FTP,
HTTP or telnet.
major
sniScCpuSpeedChanged 656 CPU speed has changed
because of temperature
problems.
informational
sniScFanAdded 653 The indicated hot-plug fan
was inserted.
informational
sniScFanRemoved 654 The indicated hot-plug fan
was removed.
informational
sniScPowerSupply
RedundancyLost
671 Power supply redundancy
no longer available.
minor
sniScRedundant
FanFailed
648 The indicated redundant
fan failed.
major
sniScRedundant
PowerSupplyFailed
649 One redundant hot-replace
power supply failed.
major
sniScShutdown
Cancelled
655 A pending server shutdown
was canceled by the user.
informational
sniScVoltageOk 650 Power supply voltage is
within normal range again.
informational
sniScVoltageTooHigh 652 Power supply voltage is too
high.
critical
sniScVoltageTooLow 651 Power supply voltage is too
low.
critical
svCommunication
Established
636 Communication with the
server management
controller was established.
informational
svCommunicationFailure 610 Communication with the
server management
controller was interrupted.
critical
tempCritical 604 The temperature has
reached a critical level.
critical
tempOk 602 The temperature is within
normal range.
informational
Trap name ID Meaning Error class
Table 40: ServerControl traps (SC.mib)