ServerView Event Manager 151
Trap overview
tapeAlertTrap23 23 The last cleaning cartridge
used in the tape drive was
an invalid type:
1. Do not use this cleaning
cartridge in this drive.
2. Wait for the current
operation to finish.
3. Then use a valid
cleaning cartridge.
critical
tapeAlertTrap29 29 Preventive maintenance of
the tape drive is required.
Check the tape drive users
manual for device specific
preventive maintenance
tasks or call the tape drive
supplier helpline.
minor
tapeAlertTrap30 30 The tape drive has a
hardware fault:
1. Eject the tape or
magazine.
2. Reset the drive.
3. Restart the operation.
critical
tapeAlertTrap31 31 The tape drive has a
hardware fault:
1. Turn the tape drive off
and then on again.
2. Restart the operation.
3. If the problem persists,
call the tape drive
supplier helpline.
critical
Trap name ID Meaning Error class
Table 44: Tape traps