Fujitsu V6.00 Server User Manual


 
156 ServerView Event Manager
Trap overview
tapeAlertTrap260 260 The library mechanism may
have a hardware fault. Run
extended diagnostics to
verify and diagnose the
problem. Check the library
users manual for device
specific instructions on
running extended
diagnostic tests.
minor
tapeAlertTrap261 261 The library has a problem
with the host interface:
1. Check the cables and
cable connections.
2. Restart the operation.
critical
tapeAlertTrap262 262 A hardware failure of the
library is predicted. Call the
library supplier helpline.
minor
tapeAlertTrap263 263 Preventative maintenance
of the library is required.
Check the library users
manual for device specific
preventative maintenance
tasks, or call your library
supplier helpline.
minor
tapeAlertTrap264 264 General environmental
conditions inside the library
have exceeded the humidity
specifications.
critical
tapeAlertTrap265 265 General environmental
conditions inside the library
have exceeded the
temperature specifications.
critical
Trap name ID Meaning Error class
Table 44: Tape traps