Fujitsu V6.00 Server User Manual


 
ServerView Event Manager 139
Trap overview
5.3.18 ServerControl traps (SC2.mib)
MIB-OID: 1.3.6.1.4.1.231.2.10.2.2.10.20
This section lists ServerControl traps in alphabetical order.
Trap name ID Meaning Error class
sc2TrapAcFail 2040 Mains failed in the specified
cabinet. This trap occurs
only in storage extension
cabinets without UPS or
BBU. A server has no time
to send this trap.
critical
sc2TrapBatteryVoltage
Prefail
2054 Battery is predicted to fail. major
sc2TrapBiosSelftest
Error
2005 A critical error occurs while
BIOS selftest. Take notice
of this error to clear the
error condition.
critical
sc2TrapBootMessage
LogEntry
2102 An error message was
written into the
systemboard's message
log. This could have
happened when an error
occurred before the server
management agents were
running or any error without
a specific trap. See server
management message log
for detailed error
description.
major
sc2TrapBootRetryCount
Zero
2095 This trap will be sent when a
boot retry counter gets zero
on power up.
major
Table 41: ServerControl traps (SC2.mib)