36 ServerView Event Manager
iRMC S2 SEL Entries and SC2 MIB Traps
190017 ’DIMM XY’: Memory
replaced by spare
memory
Memory module
’DIMM XY’ in cabinet
XY of server XY had
failed and was
replaced by a hot-
spare module.
2070 sc2TrapMem
ErrorModule
Replaced
19001A ’DIMM XY’: Memory
module failed
predicted
Memory module
failure is predicted
for module ’DIMM
XY’ in cabinet XY of
server XY.
2068 sc2TrapMem
ErrorModule
Prefail
19001F Memory: redundancy
lost
Memory
configuration in
cabinet XY of server
XY has lost
redundancy.
2074 sc2TrapMem
Error
Redundancy
Lost
190035 ’DIMM XY’: Memory
module error
Memory module
’DIMM XY’ in cabinet
XY of server XY is
failing. Too many
errors have
occurred.
2069 sc2Trap
MemError
ModuleFailing
190036 ’DIMM XY’: Memory
module failed
(disabled)
340002 Housing opened The front door or
housing of cabinet
XY was opened on
server XY.
2110 sc2Trap
Intrusion
Assertion
340003 Housing closed The front door of
housing of cabinet
XY was closed on
server XY.
2111 sc2Trap
Intrusion
Deassertion
Error
code
iRMC S2 SEL entry Trap text Trap
no.
Trap name
Table 4: iRMC S2 SEL entry - SC2 MIB trap