Fujitsu V6.00 Server User Manual


 
138 ServerView Event Manager
Trap overview
trapOnBattery 606 AC power failure. Cabinet is
running on battery power.
The UPS is operating on
battery power or the power
supply is drawing current
from the backup battery unit
(BBU). This trap is
persistent and is resent at
one minute intervals until
the mains returns or the
system is switched off.
critical
trapOnMains 607 AC power OK.
informational
uncorrectableMemError 644 Uncorrectable memory
error.
critical
uncorrectableMem
ErrorAddr
638 Uncorrectable memory
error at address.
critical
uncorrectableMemError
Bank
640 Uncorrectable memory
error in bank.
critical
uncorrectableMemError
Module
642 Uncorrectable memory
error in module.
critical
Trap name ID Meaning Error class
Table 40: ServerControl traps (SC.mib)