ServerView Event Manager 79
Alarm configuration example
4.12 Alarm configuration example
This section explains a typical example of alarm configuration.
Purpose
When an event whose severity is critical occurs on the ALARMTEST server, a
mail is sent to the administrator (admin@test.co.jp).
Requirements
– ServerView agent is running on the server, and the server is registered as a
management target in ServerView Operations Manager on the same
network.
– Test traps from the ServerView agent to ServerView Operations Manager
are functioning normally.
– ServerView Operations Manager can access the SMTP server
(111.222.3.20) while it is in operation.
Setting procedure
Ê Perform one of the following operations.
– When operating from the ServerView Operations Manager start window:
Click Alarm Configuration.
– When operating from the individual function windows:
Click Event Management – Alarm Configuration in the menu bar at the top
of the window.
The Manage Alarm Rules window opens.
Ê Click Add.
The New Name dialog box opens.
Ê Enter e.g. CriticalMail in the New Name dialog box and click OK.
Ê Click Apply, then click Next.
The Assign Servers window opens.
Ê Select the ALARMTEST server in the server list, and click the > button.