HP (Hewlett-Packard) 2510G Switch User Manual


 
7-7
Interface Access and System Information
Interface Access: Console/Serial Link, Web, and Telnet
Note If you change the Baud Rate or Flow Control settings for the switch, you
should make the corresponding changes in your console access device. Oth-
erwise, you may lose connectivity between the switch and your terminal
emulator due to differences between the terminal and switch settings for these
two parameters.
Changes to console parameters require that you perform a write memory and
then execute boot before the new console configuration will take effect. To
enable temporary and non-disruptive changes to the terminal mode without
requiring a reboot, use the console local terminal command (see page 7-8).
For example, to use one command to configure the switch with the following:
VT100 operation
19,200 baud
No flow control
10-minute inactivity time
Critical log events
you would use the following command sequence:
Figure 7-3. Example of Executing the Console Command with Multiple Parameters
The switch implements the Event Log change immediately. The switch implements
the other console changes after executing
write memory and reload.