HP (Hewlett-Packard) 2510G Switch User Manual


 
10-10
Port Status and Basic Configuration
Viewing Port Status and Configuring Port Parameters
Figure 10-7 shows sample output from the show tech transceivers command.
Figure 10-7. Example of Show Tech Transceivers Command
Operating Notes:
The following information is displayed for each installed transceiver:
Port number on which transceiver is installed.
Type of transceiver.
Product number—Includes revision letter, such as A, B, or C. If no
revision letter follows a product number, this means that no revision
is available for the transceiver.
Part number—Allows you to determine the manufacturer for a spec-
ified transceiver and revision number.
For a non-ProCurve installed transceiver (see line 23 Figure 10-7), no
transceiver type, product number, or part information is displayed. In the
Serial Number field, non-operational is displayed instead of a serial num-
ber.
The following error messages may be displayed for a non-operational
transceiver:
Unsupported Transceiver. (SelfTest Err#060)
Check: www.hp.com/rnd/device_help/2_inform for
more info.
This switch only supports revision B and above
transceivers. Check: www.hp.com/rnd/device_help/
2_inform for more info.
Self test failure.
Transceiver type not supported in this port.
ProCurve# show tech transceivers
Transceiver Technical Information:
Port # | Type | Prod # | Serial # | Part #
-------+-----------+--------+------------------+----------
21 | 1000SX | J4858B | CN605MP23K |
22 | 1000LX | J4859C | H117E7X | 2157-2345
23 | ?? | ?? | non operational |
The following transceivers may not function correctly:
Port # Message
-------- -------------------------------------
Port 23 Self test failure.