HP (Hewlett-Packard) 5991-6005 All in One Printer User Manual


 
Properties
VersionString=F.01.57
This example displays all the firmware revisions.
</>hpiLO-> show /map1/swinventory1/swid*
/map1/swinventory1/swid1
TargetType=MP FW
VersionString=F.01.57
/map1/swcollection1/swid2
TargetType=BMC FW
VersionString=01.60
/map1/swcollection1/swid3
TargetType=EFI FW
VersionString=ROM A 05.11, ROM B 255.255
/map1/swcollection1/swid4
TargetType=System FW
VersionString=ROM A 62.03, ROM B 255.255, Boot ROM B
/map1/swcollection1/swid5
TargetType=PDH FW
VersionString=00.0b
/map1/swcollection1/swid6
TargetType=UCIO FW
VersionString=03.03
/map1/swcollection1/swid7
TargetType=PRS FW
VersionString=00.05 UpSeqRev: 09, DownSeqRev: 07
or
</>hpiLO-> show -level all swid*
Firmware Upgrade
Firmware upgrades enhance the functionality of iLO 2 MP.
The MP firmware is packaged along with system, BMC, and FPGA/PSOC firmware. You can
download and upgrade the firmware package from the HP website at:
http://www.hp.com/go/bizsupport.
IMPORTANT: When performing a firmware upgrade that contains system programmable
hardware, you must properly shut down any OS that is running before starting the firmware
upgrade process.
Select the download for Integrity firmware and follow the directions provided in the release
notes.
After the upgrade, reconnect and log in as user Admin and password Admin (case sensitive).
Remote Access Configuration
The iLO 2 MP supports the use of telnet and SSH to access the iLO 2 MP command line interface.
Telnet SM CLP Targets
This section describes targets, their properties, and supported verbs necessary to enable or disable
telnet access to the iLO 2 MP.
136 Using iLO 2 MP