HP (Hewlett-Packard) 5991-6005 All in One Printer User Manual


 
HE displays the MP hardware and firmware version identity, and the date and time of firmware
generation.
If executed from the MP Main Menu, HE displays general information about the iLO 2 MP
and those commands available in the MP Main Menu.
If executed in command mode, HE displays the MP Help: Command Menu List. HE also
displays detailed help information in response to a topic or command at the help prompt.
Command line usage and scripting:
HE [ -topic | command ] [ -nc ]
-?
ID: System information settings
Command access level: MP configuration access
ID displays and modifies the following:
SNMP contact person Name, telephone, e-mail, and pager number.
Server information Location, rack ID, position, asset tag.
System host name The system host name of the operating system.
NOTE: The system host name information is not retained across
iLO 2 MP reboots.
Command line usage and scripting:
ID [ { -host [ <text> ] }
| { -person [ -name <text> ] [ -telephone <text> ]
[ -email <text> ] [-pager <text> ] }
| { -server [ -location <text> ] [ -rackid <text> ]
[ -position <text> ] } ]
[ -tag <text> } ] [ -nc ]
-?
IT: Inactivity timeout settings
Command access level: MP configuration access
IT prevents sessions on the system from being inadvertently left open. When you initiate an iLO
2 MP command, other users are prohibited from running any commands until the first command
has been completed or until it times out. Command interface inactivity timeout specifies that
timeout value. This prevents a user from inadvertently keeping the iLO MP locked in a command,
preventing other users from running iLO 2 MP commands.
NOTE: The iLO 2 MP command interface inactivity timeout cannot be deactivated.
Use the flow control timeout to prevent any user who is using a terminal that does not obey flow
control from locking the system out from other users.
The following are IT command parameters:
iLO 2 MP inactivity timeout One to 30 minutes (default is three minutes).
Flow control timeout Zero to 60 minutes. If the flow control timeout is set to
zero, no timeout is applied. A mirroring flow control
condition ceases when no flow control condition exists on
any port. This timeout prevents mirrored flow control from
blocking other ports when inactive.
Command line usage and scripting:
IT [ -command <n> ] [ -flow <n> ] [ -nc ]
-?