“H” Group: Motor Constants Functions
Configuring
Drive Parameters
3–44
H204 Motor poles setting, 2nd
motor
Four selections:
2 / 4 / 6 / 8
✘ 4 4 4 poles
2AUXP 4p
H_05 Motor speed constant Motor proportional gain
constant (factory set),
range is 0 to 99
✘ 20 20 20 —
AUX KP 20
H205 Motor speed constant,
2nd motor
Motor proportional gain
constant (factory set)
range is 0 to 99
✘ 20 20 20 —
2AUXKP 20
H_06 Motor stabilization
constant
Motor constant (factory set),
range is 0 to 255
✘ 100 100 100 —
AUX KCD 100
H206 Motor stabilization
constant, 2nd motor
Motor constant (factory set),
range is 0 to 255
✘ 100 100 100 —
2AUXKCD 100
H_20 Motor constant R1 Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53
✘ Factory set according
to inverter model
Ohms
AUX R1 05.700*
H220 Motor constant R1, 2nd
motor
Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53
✘ Factory set according
to inverter model
Ohms
2AUXR1 05.700*
H_21 Motor constant R2 Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53
✘ Factory set according
to inverter model
Ohms
AUX R2 02.773
H221 Motor constant R2, 2nd
motor
Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53
✘ Factory set according
to inverter model
Ohms
2AUXR2 02.773
H_22 Motor constant L Range is 0.00 - 655.3 mH,
0.00 to 99.99
100.0 - 655.3
✘ Factory set according
to inverter model
mH
AUX L 045.70mH
H222 Motor constant L,
2nd motor
Range is 0.00 - 655.3 mH,
0.00 to 99.99
100.0 - 655.3
✘ Factory set according
to inverter model
mH
2AUXL 045.70mH
H_23 Motor constant I
o
Range is 0.00 to 655.3 Amps,
0.00 to 99.99
100.0 - 655.3
✘ Factory set according
to inverter model
Arms
AUX I0 001.50A
H223 Motor constant I
o
, 2nd
motor
Range is 0.00 to 655.3 Amps,
0.00 to 99.99
100.0 - 655.3
✘ Factory set according
to inverter model
Arms
2AUXI0 001.50A
“H” Function
Run
Mode
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
Units