Hitachi SJ100 Power Supply User Manual


 
SJ100 Inverter
Configuring
Drive Parameters
3–7
Trip Event and History Monitoring
The trip event and history monitoring feature lets you cycle through related information
using the keypad. See
Monitoring Trip Events, History, & Conditions” on page 6–5 for
more details.
D_07 Scaled output frequency
monitor
Displays the output frequency
scaled by the constant in B_86.
Decimal point indicates range:
XX.XX 0.01 to 99.99
XXX.X 100.0 to 999.9
XXXX. 1000 to 9999
XXXX 10000 to 99990
—Hz
/Hz01.0 0.00
“D” Function
Run
Mode
Edit
Range
and
Units
Func.
Code
Name /
SRW Display
Description
“D” Function
Run
Mode
Edit
Range
and
Units
Func.
Code
Name /
SRW Display
Description
D_08 Trip event monitor Displays the current trip event.
information.
——
ERR1 EEPROM
ERR1 0.0Hz
ERR1 0.0A
ERR1 324.3Vdc
ERR1 RUN 000000H
D_09 Trip history monitor Displays the previous two
events and their causes.
——
ERR2 EEPROM
ERR2 0.0Hz
ERR2 0.0A
ERR2 330.0Vdc
ERR2 RUN 000000H
ERR3 EEPROM
ERR3 0.0Hz
ERR3 0.0A
ERR3 328.7Vdc
ERR3 RUN 000000H
Cumulative operation
RUN time monitor
Displays total time the inverter
has been in RUN mode in
hours.
hours
RUN 000000H
Trip count Displays cumulative number of
trip events.
—trips
ERROR COUNT 009